S-PARAMETER

AcronymDefinition
S-PARAMETERTransistor Scattering Parameter
References in periodicals archive ?
In order to understand an S-Parameter model better and do some basic quality checks, some type of S-Parameter data viewer is highly recommended, such as Mentor Graphics' HyperLynx TouchStone Viewer, shown in FIGURE 4.
There are also tools on the market today that that will also allow you to cascade several S-parameter blocks and get a combined result of much larger structures.
The first method is to model the fixture using an EM simulator and use the S-parameter results of the simulation to de-embed (remove) the effects of the fixture.
The authors would like gratefully to acknowledge the Department of Electrical Engineering of James Cook University for providing the equipment for S-parameter measurement.
Unlike the conventional training process [8, 11, 12], the output data of the adopted neural networks is not available, in the proposed modeling procedure, the outputs of the neural networks will be sent to the intrinsic part of equivalent circuit and conduct the S-parameter simulation with the whole equivalent circuit.
Furthermore, the VNA 2 Port S-Parameter measurement is a very sensitive method for obtaining insertion loss on cable assemblies that include couplers (MIL STD 1553) and stubs that are hard to disconnect physically.
After calculating the S-parameter of the network, the required 7-parameter can be calculated by [9].
To see the effectiveness of our proposed antenna system, we perform simulations for the S-parameter and the current flow.
Calculated response of the proposed NGD topology with [M.sub.S1] = 0.74, [Q.sub.u] = 50, [DELTA] = 2%: (a) S-parameter magnitudes and (b) phase/group delay characteristics.
The advantages (e.g., smaller via dimension and via stub removal) and challenges (e.g., crosstalk due to smaller inter-pair separation) of HDI are studied by analyzing the S-parameter, time-domain reflectometry (TDR) and transmissionline eye diagrams obtained by three-dimensional electromagnetic modeling (3DEM) and 2-D electromagnetic modeling (2DEM) using Mentor Graphics' HyperLynx and Keysight Advanced Design System (ADS) CAD software.
The [mathematical expression not reproducible] stands for the measured S-parameter and [S.sub.11] for the reference S-parameter.
is pleased to welcome IPDiA to the Modelithics Vendor Partner (MVP) Program, and announce the development of three new S-Parameter (SPAR) models for IPDiA ultra-broadband surface mount silicon capacitors.