SFRC

(redirected from Steel Fiber Reinforced Concrete)
AcronymDefinition
SFRCSenate Foreign Relations Committee
SFRCSchool of Forest Resources and Conservation
SFRCSteel Fiber Reinforced Concrete
SFRCSouth Florida Research Center (Everglades National Park; Homestead, FL)
SFRCShort Form Research Contract
SFRCSan Francisco Rowing Club (California)
References in periodicals archive ?
However, SFCRC20 falls in Zone A (3.66-4.58 km/sec) which could be suggested as a limited ratio of rubber aggregate incorporated in steel fiber reinforced concrete. For fibrous concrete, the inclusion of crumb rubber aggregate improved its capacity to absorb the transit velocity, which can be considered as a good material for sound absorption and with suitable strength to resist structural loading.
Liu, "Study of flexural toughness of steel fiber reinforced concrete," Journal of Shenyang Jianzhu University, vol.
[16.] Ganesan, N., and Ramana Murthy, J.V., Studies on Confined Steel Fiber Reinforced Concrete, The Indian Concrete Journal, November 1990.
Typical stress-strain ([sigma]-[epsilon]) curve for silica fume concrete and steel fiber reinforced concrete is shown in Fig.
High performance steel fiber reinforced concrete and vertically laminated wood were combined to create a composite deck.
Li, "Experimental investigation on the stress-strain of steel fiber reinforced concrete subjected to uniaxial cyclic compression," Construction and Building Materials, vol.
Part III-2: method of tests for steel fiber reinforced concrete," Concrete library of JSCE, vol.
Tenders are invited for Construction Materials Such as Grouting Admixture Chemicals for Carrying out Grouting work to Concrete Masonry Dam Work and M60 Silica fume steel fiber reinforced concrete and quotation rates also required for Carrying out the Specialised items of works such as Zinc Metalizing Poly Urethane Grouting etc
The inclusion of the fibers into the concrete mix influence its workability (Hannat, 1978; Swamy, 1974) ACI committee report in 1996,reported that in the typical ranges of volume fractions used for steel fiber reinforced concrete (0.25 to 1.5 volume present),the addition of steel fiber reduced the measured slump of the composite as compared to plain concrete in the range of 25 to 102mm.Incorporation of super plasticizer is essential to maintain good workability (120-150mm).Steel fiber improves the ductility of concrete under all modes of loading.
This recommendation was chosen because it does not require previous knowledge of the tensile stress-strain relationship of steel fiber reinforced concrete. In this recommendation, shear strength provided by concrete and fibers (Vc and Vcf) was calculated separately.
Orientation factor and number of fibers at failure plane in ring-type steel fiber reinforced concrete, Cement and Concrete Research 40(5): 810-819.